Hydac
AEV Series Automatic Air Vent Valves
AEV Series Automatic Air Vent Valves
Key Features
Operating Pressure Range
- P min 43 psi (3 bar)
- P max 8700 psi (600 bar)
Material
- Carbon Steel
Operating Flow Range
- Q min 0.25 gpm (1 l/min)
- Q max 15 gpm (57 l/min) to achieve higher flow rates, parallel connection is possible
Model Code
- AEV - 6 / 5
- Part Number 00230223
The HYDAC Air Vent Valve eliminates air bubbles which accumulate in hydraulic systems immediately after start-up or after long periods of shut-down of the system.
The Air Vent Valve remains open until the valve reaches a 45 psi differential pressure.
Pressure must be maintained above 45 psi to keep valve closed.
This type of operation of the HYDAC Air Vent Valve allows for easy start-up of hydraulic systems.
Due to the compact design the Air Vent Valve requires minimum space.
Catalogs