Parker Pneumatic
PXP Pneumatic Two Hand Start

The pre-assembled two-hand control enclosure occupies both hands of an operator by requiring nearly simultaneous operation of two pushbuttons.

Part Number: PXPC111 

Click to Enlarge

  • Poppet – snap-acting (no spools)
  • Same air as in cylinders – Filtration: 40 micron
  • No lubrication required 

Operating Pressure........................40 to 120 PSI (3 to 8 bar)

Permissible Fluids –

Air or neutral gas 40 micron filtration, lubricated or dry

Flow at 90 PSI (6 bar)...................... 7 SCFM (200 l/mn ANR)

Operating Temperature...........-5°F to 140°F (-15°C to 60°C)

Below 40°F (5°C), an air dryer is required

Storage Temperature.............-40°F to 160°F (-40°C to 70°C)

Number of operations with dry air at 90 PSI (6 bar),

68°F (20°C), frequency 1 Hz................... 1 Million Operations

Vibration resistance –

Conforms to section 19-2 of bureau Véritas regulations

(November 1987)

Materials –

Body........................................................ Glass Filled Nylon

Operating Head................................ Zinc Alloy and Plastic

Connections:....................................................... 5/32" instant