Parker Hydraulic Group
D1FP Direct operated proportional DC valve

Key Features

  • Servovalve dynamics: -3dB/350Hz at ±5% input signal
  • Full flow capacity up to 350 Bar (5075 PSI) pressure drop through the valve.Maximum tank pressure 350 Bar (5075 PSI) with external drain Y-port
  • High flow
  • Defined spool positioning in case of loss of electric power supply
  • Defined spool positioning at power-down
  • Onboard electronics

Click to Enlarge

Series D1FP direct operated control NG6 (CETOP 3) valve features extremely high dynamics combined with maximum flow. It is used for high accuracy in positioning of a hydraulic axis, and for controlling force and velocity.

Driven by the new patented VCD® actuator, the D1FP reaches the frequency response of servo valves. Compared with solenoid driven valves, the D1FP can also be used in applications with pressure drops up to 350 Bar (5075 PSI) across the valve. Because of the high flow capability, the D1FP can be a substitute for NG10 valves in some cases.

At power-down, the spool moves in a defined position.

All common input signals are available.

Catalogs